High Quality Karl-Fischer(kf) Auto Moisture Titration Instrument
$1,758.00 – $6,580.00
KFT-20V Karl Fischer Coulometer is suitable for the determination of samples containing trace moisture such as organic solvents and oils. Moisture range: 10ug~20mg; KFT-40C Karl Fischer Titrator Support KF Titration Mode and Titer Detection Mode. Moisture range: 0.mg~250mg ;KFT-40VC Karl Fischer Titrator moisture analyzer supports the measurement of moisture content in the full range including volumetric method and coulometric method, and meets the measurement needs of constant moisture and trace moisture.
- Description
- Additional information
Description
KFT-20V Karl Fischer Coulometer
KFT-20V Karl Fischer Coulometer trace moisture analyzer is suitable for the determination of trace liquid samples.It is commonly used to measure samples with low water content.
Feature:
LCD display screen.
Generator cell with diaphragm.
Selectable units including μg, mg, %, mg/L, g/L, etc.
Settable parameters, including measurement unit, polarization current, generator current, endpoint potential, stop criterion and etc.
Data can be stored and easily transferred to printer via RS-232 communication interface.
Reset feature automatically resumes all settings back to factory default options.
Includes:
JB-11 stirrer
Electrolysis electrode
Work electrode
Specification:
Model | KFT-20V | |
Coulometric Ttration | Range | 10ug~20mg |
Polarization Current Accuracy | ±0.2μA | |
Working Current | 10mA, 20 mA, 50 mA, 100 mA | |
Working Current Accuracy | 0.5% | |
Accuracy | ± (5%+3) μg | |
Repeatability | ±3% | |
General | Power Supply | AC Adapter, 200-240 VAC input |
Dimension (mm) & Weight (kg) | 300×235×100; 3 |
KFT-40C Karl Fischer Titrator
KFT-40C Karl Fischer Titrator equipped with anti leakage device and anti back suction device of waste liquid bottle.it support full automatic liquid inlet and discharge, KF reagent mixing and automatic cleaning , anti titration cup solution overflow protection function.Moreove,it also support prevent users from directly contacting KF reagent and ensure the measuring and environment safety.
Feature:
LCD display screen.
Support KF Titration Mode and Titer Detection Mode.
Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
Selectable units including mg, mg/L, %, ppm, etc.
Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
Store up to 200 titration data sets (GLP-compliant).
Data can be easily transferred to printer via RS-232 commnication interface.
Reset feature automatically resumes all settings back to factory default options.
Includes:
Measuring electrode
10ml burette
Volumetric titration cell
Specification:
Model | KFT-40C | |
Volumetric Titration | Range | 0.1mg~250mg |
Polarization Current Accuracy | 0.1mg | |
Working Current | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ±0.5% | |
General | Power Supply | AC Adapter, 100-240 V AC input |
Dimension (mm) & Weight (kg) | 340×400×400; 10 |
KFT-40VC Karl Fischer Titrator
KFT-40VC Karl Fischer Titrator moisture analyzer supports the measurement of moisture content in the full range including volumetric method and coulometric method, and meets the measurement needs of constant moisture and trace moisture.
Features:
GENERAL FEATURES
LCD display screen.
Titration methods, curves and results are displayed in detail.
Volumetric KF Titration and Coulometric KF Titration are supported.
Data analysis feature helps user review and compare results.
Data can be easily transferred to printer via RS-232 communication interface.
Reset feature automatically resumes all settings back to factory default options.
Volumetric Karl Fischer Titration
Support KF Titration Mode and Titer Detection Mode.
Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
Automatic/manual background drift correction ensures accurate results.
Selectable units including mg, mg/L, %, ppm, etc.
Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
Store up to 200 titration data sets (GLP-compliant).
Coulometric Karl Fischer Titration
Generator cell with diaphragm.
Automatic/manual background drift correction ensures accurate results.
Selectable units including μg, mg, %, ppm, mg/L, μg/mL, etc.
Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.
Store up to 200 titration data sets (GLP-compliant).
Includes:
External device
Electrolysis electrode
Measuring electrode
10ml Burette
Volumetric titration cell
Coulometric titration cell
Specification:
Model | KFT-40VC | |
Volumetric Titration | Range | (0.1mg~250)mg |
Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ±0.5% | |
Coulometric Titration | Range | 10μg~20mg |
Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
Working Current | 1, 1.86, 5, 10μg (H2O)/S | |
Accuracy | ± (5%+3) μg | |
Repeatability | RSD of 100μg sample measurement result ≤3% | |
General | Power Supply | AC Adapter, 100-240 V AC input |
Dimension (mm) & Weight (kg) | 340×400×400; 10 |
Additional information
Model | KFT-20, KFT-40C, KFT-40VC |
---|